Reactive Power Compensation Controller Power Factor Correction

Customization: Available
Type: Power
Structure: Protection

Products Details

Basic Info.

Model NO.
controller4
Certification
ISO9001:2000, CCC
Form
All- packaged Type
Operation Voltage
Low Voltage
Size
1 Uint
Application Range
Power Plants
Shell Material
PVC
Shell Protection Grade
IP56
Brand
Huakun
Rated Voltage
AC380/AC220V+-10%
Rated Current
AC0-5A
Rated Frequency
50Hz+-5%
Sensitivity
100mA
Switching Delay
1-250s
Transport Package
Carton Package
Specification
113*113mm
Trademark
Huakun
Origin
Shanghai, China
Production Capacity
100000PCS/Year

Packaging & Delivery

Package Size
9.20cm * 9.00cm * 6.80cm
Package Gross Weight
1.000kg

Product Description

Reactive Power Compensation Controller Power Factor CorrectionReactive Power Compensation Controller Power Factor CorrectionHKK-JKW series of reactive power automatic compensation controller (referred to as controller) is a special equipmentfor low-voltage distribution system to compensate reactive power. It is designed according to the industry standard JB/T9663-2013 and the power standard DL/T597-1996. lts sampling physical quantity is reactive power, with novel design,many functions, good control performance, high reliability advantages, in the domestic similar products in a leadingposition, for distribution automation provides a new equipment.
Reactive Power Compensation Controller Power Factor Correction1.Power supply voltage: rated at 220V or 380V, fluctuation shall not exceed ±10%;
2.Ambient temperature:-25°ºC~55C;
3.Relative humidity: The maximum relative temperature is 90%/(20°c ,4.Altitude: no more than 2000m; 5.Environmental conditions: no explosive inflammable dangerous media,no corrosive metal gases and conductive dustdamaging electrical insulation.
Reactive Power Compensation Controller Power Factor Correction
1.Basic parameters Rated voltage: AC380/AC220V±10%
Rated current ACO-5A Rated frequency: 50Hz±5%
2.Measurement accuracy
Voltage: ±1.0%; Current: ±1.0%;
Powerfactor: ±1.0%;
Reactive power:±2.0%.
3.Control parameters
Sensitivity:100mA Target Cos preset: 0.70-1.00; Step 0.01; Factory preset 0.95;
Switching delay: 1-250s; Overvoltage protection: 380-500/230-260v;Step 1 v.Back to the poor 6 V.
Undervoltage protection: 340V/180V; Back to the poor 6v. CT changes: 50/5A-4000/5A Step 1; Capacitance: 0-125kvar each branch factory preset 5Kvar;
Contact capacity: 380V*5A/220V*7A per branch.
Reactive Power Compensation Controller Power Factor CorrectionReactive Power Compensation Controller Power Factor CorrectionReactive Power Compensation Controller Power Factor CorrectionReactive Power Compensation Controller Power Factor CorrectionReactive Power Compensation Controller Power Factor Correction
Reactive Power Compensation Controller Power Factor Correction Reactive Power Compensation Controller Power Factor Correction
Reactive Power Compensation Controller Power Factor Correction

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours