- Overview
- Working Principle
- Product Description
- Project Case
- Manufacturing Shop
- Product Parameters
- Product Packing
Basic Info.
Model NO.
AHF
Installation
Wall-Mount, Frame-Mount
Transport Package
Wooden Case
Specification
can be customized
Trademark
ARK
Origin
China
Product Description
The working principle of the STD APF series active power filter is to detect the load current in real time, separate the harmonic currents one by one based on the specified harmonic current detection algorithm, and generate and control the driver IGBT output and load harmonic current according to the set filtering percentage. Compensation currents with the same amplitude and opposite phases achieve the purpose of harmonic cancellation.

COMPACT HIGH PERFORMANCE
* Wall mount or cabinet mount in an ultra-compact design
* Modular design, convenient multi-module parallel, small footprint, easy maintenance
* Independent air duct and independent plate bin structure design to ensure the stable operation of equipment.
* Wall mount or cabinet mount in an ultra-compact design
* Modular design, convenient multi-module parallel, small footprint, easy maintenance
* Independent air duct and independent plate bin structure design to ensure the stable operation of equipment.
OPTIMAL HARMONIC MITIGATION
* Harmonic compensation rate>92%
* Selection of odd and even harmonics up to the 50th order
* High efficiency >97%
* Reaction time <100us Response time of <10ms
* Harmonic compensation rate>92%
* Selection of odd and even harmonics up to the 50th order
* High efficiency >97%
* Reaction time <100us Response time of <10ms
PROTECT YOUR SYSTEM FROM RESONANCE.
* The current spectrum is analysed at 1024 individual points per cycle
* System impedance at each individual harmonic is effectively 'learnt' by the AHF
* Compensation current is slowly increased with system stability closely monitored
* Should resonance be detected at any point the intelligent FFT can skip the problematic point
BALANCE YOUR LOADS AND CORRECT YOUR POWER FACTOR TOO
* In addition to harmonic mitigation the AHF can provide load current balancing
* Reactive power can be compensated for thus increasing power factor
* System impedance at each individual harmonic is effectively 'learnt' by the AHF
* Compensation current is slowly increased with system stability closely monitored
* Should resonance be detected at any point the intelligent FFT can skip the problematic point
BALANCE YOUR LOADS AND CORRECT YOUR POWER FACTOR TOO
* In addition to harmonic mitigation the AHF can provide load current balancing
* Reactive power can be compensated for thus increasing power factor






TYPE | Series 220V | Series 400V | Series 500V | Series 690V |
Max neutral wire current | 23A | 15A ,25A ,50A, 75A ,100A ,150A | 100A | 100A |
Nominal voltage | AC220V(-20%~+20%) | AC380V(-20%~+20%) | AC500V(-20%~+20%) | AC690V(-20%~+20%) |
Rated frequency | 50Hz±5% | |||
Network | Single phase | Three-phase three-wire/three-phase four-wire | ||
Response time | <40ms | |||
Harmonics filtering | 2th to 50th Harmonics,The number of compensation can be selected, and the range of single compensation can be adjusted | |||
Harmonic compensation rate | >92% | |||
Neutral line filtering capability | / | The filtering capacity of three-phase four-wire neutral line is 3 times of that of phase filtering | ||
machine efficiency | >97% | |||
Switching frequency | 32kHz | 16kHz | 12.8kHz | 12 .8kHz |
Feature selection | Deal with harmonics/Deal with harmonics and reactive power | Deal with harmonics/Deal with harmonics and reactive power/ Deal with harmonics and three-phase unbalance /Three options | ||
Numbers in parallel | No limitation. A single centralized monitoring module can be equipped with up to 8 power modules | |||
Communication methods | Two-channel RS485 communication interface (support GPRS/WIFI wireless communication) | |||
Altitude without derating | <2000m | |||
Temperature | -20~+50°C | |||
Humidity | <90% RH,The average monthly minimum temperature is 25ºC without condensation on the surface | |||
Pollution level | Below level 3 | |||
Protection function | Overload protection, hardware over-current protection, over-voltage protection, power failure protection, over-temperature protection, frequency anomaly protection, short circuit protection, etc | |||
Noise | <50dB | <60dB | <65dB | |
Installation | Rack/wall hanging | Rack | ||
Into the way of line | Back entry (rack type), top entry (wall-mounted) | Top entry | ||
Protection grade | IP20 |